Hitachi Energy
Unit ESW has System Release R16B Status
All units need to run
the latest embedded software (ESW) that had been released in the scope of the FOX61x system release R16B,
i.e. the units and their ESW are of the types and versions shown in Table Upgradeable Units and ESW with System Release R16B.
 
Upgradeable Units and ESW with System Release R16B 
Unit name
Upgrade from
To
R16B ESW 1
R18 ESW 2
CESM1, CESM1-F
cesun_r16b04_11
cesun_r18a01
CESM1 (NE Controller)
cesne_r16b04_11
cesne_r18a01
CESM2, CESM2-F
cesun_r16b04_11
cesun_r18a01
CESM2 (NE Controller)
cesne_r16b04_11
cesne_r18a01
CESM3
cesm3_r16b04_11
cesm3_r18a01
CEPI1 (R1, R2 HW)
cepi1_r4b07_01
No upgrade required; keep ESW version.
COSI1
cosi1_r4b02_03
No upgrade required; keep ESW version.
DATI1
dati1_r5e02_11
No upgrade required; keep ESW version.
DEFM1, DEFM1-F
defm1_r16b04
defm1_r18a01
ELET1
elet1_r16b04_11
elet1_r18a01
EPEX1
epex1_r16b04
epex1_r18a01
EPOI1
epoi1_r16b04
epoi1_r18a01
EPSI1
epsi1_r2c02_11
No upgrade required; keep ESW version.
EROP1, EROP1-F
erop1_r16b04_11
erop1_r18a01
ESOP1, ESOP1-F
esop1_r16b04_11
esop1_r18a01
ESPO1
espo1_r16b04_11
espo1_r18a01
ETOP1, ETOP1-F
etop1_r16b04_11
etop1_r18a01
FOX610 (Unit)
f10un_r1b604_11
f10un_r18a01
FOX610 (NE Controller)
f10ne_r1b604_11
f10ne_r18a01
LECO1
leco1_r1d03_02
No upgrade required; keep ESW version.
leca1_r1a02_04
No upgrade required; keep ESW version.
LEDA1
leda1_r2d02_02
No upgrade required; keep ESW version.
LEDE1 R1 HW
lede1_r5c02_02
No upgrade required; keep ESW version.
LEDE1 R2 HW
lede1_r17a01_01
lede1_r18a01
LEDS1 R1 HW
leds1_r2g02
No upgrade required; keep ESW version.
LEDS1 R2 HW
leds1_r16c02
leds1_r18a01
LESU1
lesu1_r2d03
No upgrade required; keep ESW version.
LEXI1
lexi1_r2c03_05
No upgrade required; keep ESW version.
ODIS1 R1 HW
odis1_r16b04_11
odis1_r18a01
ODIS1 R2 HW
odis1r2_r16c02_03
odis1r2_r18a01
OPIC1
opic1_r1d02_01
opic1_r1d02_02
OPIC2 R1 HW
opic2_r16b04_11
opic2_r18a01
OPIC2 R2 HW
opic2r2_r16c02_03
opic2r2_r18a01
SAMO1
samo1_r3g01_06
No upgrade required; keep ESW version.
SAMO2, SAMO2-F
samo2_r16b04_11
samo2_r18a01
SAMO3
samo2_r16b04_11
samo2_r18a01
SAMO5, SAMO5-F
samo2_r16b04_11
samo2_r18a01
SENC1, SENC1-F
No upgrade possible.
No upgrade possible.
SENC1-4, SENC1F4, SENC1-8, SENC1F8
app-416_r16b03_01
TEGO1
tego1_r16b04
tego1_r18a01
TEPI1
tepi1_r2b02
tepi1_r2c01
TEPI2
tepi2_r16b04_11
tepi2_r18a01
VFTLF
vftlf_ r1a06
No upgrade required; keep ESW version.

1 The latest version, including hotfixes (where available) is required. If the ESW is not on the mentioned version yet, first upgrade to this version.

2 Use the latest version available in accordance with the FOX61x R18 Release Note or the latest hotfix where available. Hotfixes may have been published after this document was issued.

* 
Please note: 
Make sure that, prior to the upgrade from R16B, you have installed the latest ESW that corresponds to the versions released with the system release R16B, including the latest hotfix where available, for all units in any network element to be upgraded.
If you have a unit or ESW that is not listed in Table Upgradeable Units and ESW with System Release R16B, please contact Hitachi Energy technical support (see section Technical Support).
If you have units running embedded software of a system release that is older than what is listed in Table Upgradeable Units and ESW with System Release R16B, please contact Hitachi Energy technical support (see section Technical Support).