Cold Standby
Under normal operation it is expected that the database and system files are backed up on a regular basis. In case of failure of the main workstation or server, the operator must:
Make sure that the workstation ports are connected to the management network (i.e. the LAN port is connected).
Manually start the core services on the cold standby system.
Connect the clients to the cold standby system once it is up and running.
The requirements for this solution are:
A second workstation or server – with the same Hardware configuration as the main one, with FOXMAN-UN installed;
A second FOXMAN-UN license & key for the new hardware.
Setting up the Main/Standby configuration with the two servers, and selecting “Cold Standby” for the standby server.
This solution is sufficient to provide a standby concept with a recovery time of approximately 10 min. It requires manual intervention.