np.conf
 
np_querylistmaxsize
Defines the maximum number of entries returned from a query. The default is “10000”.
np_max_applicationmanager
Defines the maximum number of NP sessions that can be concurrently performing edit operations. The default is “5”.
np_max_elementmanager
Defines the maximum number of Element Agents (Downloads) that can be concurrently under control of an NP session. The default is “5”.
np_circuit_data_fields
Defines the names and number of the data fields that are offered in the circuit dialog, to describe an individual circuit. By changing the names or adding or removing them, the number of descriptive attributes for circuits can be customized to suit the operators' requirements.
np_circuit_ep_data_fields
Defines the names and number of the data fields that are offered in the end point dialog, to describe an individual circuit end point. By changing the names or adding or removing them, the number of descriptive attributes for each circuit end point can be customized to suit the operators' requirements.
np_service_values_list
Defines the names and number of the menu items that are offered in the “Services” Combo selection box of the circuit dialog, to describe what service is being offered by an individual circuit. By changing the names or adding or removing them, the number of types of circuits can be customized to suit the operators' requirements.
np_ttp_autoactivation
If this is true, set external TTP active when creating circuits with NP. The default is “true”.
np_tti_autosetting
If this is true, set default TTI of TTP active when creating trails with NP. The default is “true”.
np_report_dir
Defines the default repository directory when creating NP reports.
path_cost_calc_model
Defines the calculation model for cost based routing. The following values are supported:
1 CostWorking + CostProtecting
2 (CostWorking + CostProtecting) / 2
3 (CostWorking * CostProtecting) / (CostWorking + CostProtecting)
Default is “1”, the parameter is disabled by default.
trail_data_koap_support
Add this parameter with option “true” for the FOX61x units to be reported to NP.
trail_data_xmlrpc1_support
Add this parameter with option “enable” for FOX660 support in NP.
trail_data_xmlrpc1_temp_support
Add this parameter with option “enable” for FOX660 support in NP.
np_conflict_detect_channels
Add this parameter with option “enable” to provide finer granularity for conflict detection.
Default is “disable”.
np_use_topote_in_avoidne_check
Add this parameter with option “true” to make sure that “Avoided NEs” is also considering intermediate NEs to be avoided when routing topological TEs, and not only A-End and Z-End NEs of found trails. NP service (nem-np-networkmgr.service) needs to be restarted for this option to take effect.
np_service_sync_add
Enable adding a circuit at deployment to the service supervision:
np_service_sync_add   enable
Default is: “disable”1.
np_service_sync_add_related
Enable adding A-Ports / Z-Ports of the circuit to the service supervision:
np_service_sync_add_related   enable
Default is: “disable”1.
np_service_sync_add_sections
Enable adding circuit sections to the service supervision:
np_service_sync_add_sections   enable
Default is: “disable”1.
np_service_sync_del
Enable deletion of a circuit from service supervision at circuit removal:
np_service_sync_del   enable
Default is: “disable”1.