Post-upgrade steps
If you are using Service Supervision and you have VPWS system services with service supervision enabled,
Proceed as follows:
1. Disable service supervision for all such VPWS system services. This can be done from the ENP GUI, VPWS tab.
• Wait until all VPWS are removed from the Service Supervisor.
2. Execute a “Clear and Synchronize” from the ENP menu option “Network - Clear and Synchronize”.
• This menu option requires Expert Mode to be active. To activate it, select “Options - Expert Mode” from the ENP menu.
3. Enable service supervision for all previous VPWS system services. This can be done from the ENP GUI, VPWS tab.
• Wait until all VPWS are listed again in the Service Supervisor.
End of instruction
In certain cases, some MPLS-TP services may appear as “Deployed Invalid” in ENP after the database has been restored and the FOXMAN-UN services are started. This may be the case e.g. if modifications to the MPLS-TP configuration made with FOXCST have not been loaded to the FOXMAN-UN database. The following steps will resolve this.
Proceed as follows:
1 Execute a force poll on all nodes.
2 Check the services status again in ENP.
3 If there are still services with status “Deployed Invalid”, execute a “Clear and Synchronize” in ENP by selecting the menu option “Network - Clear and Synchronize”. This menu option requires Expert Mode to be active. To activate it, select “Options - Expert Mode” from the ENP menu.
“Clear and Synchronize” will clear the services from the database and load them again from all nodes in the network. Wait until this has been terminated. The services should now all have “Deployed Valid” status.
4 Align all ENP services (VPLS and VPWS) from the ENP main window that are not aligned.
End of instruction
In case VPWS services are added to service supervision, VPWS services from previous releases that are using PWAC ports are missing those PWAC ports in the service supervision. VPWS modeling in Service Supervision was missing the PWAC ports. This is now fixed in R18.
To update the existing VPWS supervision from previous releases with the PWAC ports,
Proceed as follows:
1. Execute the command “Reload Configuration” from the service context menu in the ENP legacy application for the affected VPWS services. This will add the missing PWAC ports to the Service Supervision model of the VPWS services.
End of instruction