Network Requirements
Full mesh of MPLS-TP tunnels between the three nodes.
The application transports an untagged Ethernet signal over a packet network using an Ethernet port of a FOX61x:
The Ethernet signal is connected to ELET1 unit.
The core unit encapsulates the user Ethernet traffic MPLS-TP tunnels.
VPWS
A point-to-point VPWS has to be created by ENP between NE80 and NE82.
VPLS
A VPLS instance has to be created by ENP between NE80, NE82 and NE83.
NE81 does not participate in the VPLS instance.
Mesh Pseudo wire Binding.
 
Sample Settings for VPWS / VPLS
NE/Unit
Slot/port
Port type/role
VLAN
Port mode
NE80 (VPLS NE): Global ID:1; Node ID:80
CESM1
11/3
MPLS-TP
 
 
 
11/4
MPLS-TP
 
 
ELET1
20/1
PWAC
 
 
 
20/2
CVP
700
Access
NE81: Global ID:1; Node ID:81
CESM1
11/3
MPLS-TP
 
 
 
11/4
MPLS-TP
 
 
NE82 (VPLS NE): Global ID:1; Node ID: 82
CESM1
11/3
MPLS-TP
 
 
 
11/4
MPLS-TP
 
 
ELET1
16/2
PWAC
 
 
 
16/3
CVP
800
Access
NE83 (VPLS NE): Global ID: 1; Node ID:83
CESM1
11/3
MPLS-TP
 
 
 
11/4
MPLS-TP
 
 
ELET1
14/24
CVP
700
Access