Check the Encryption Parameters of the MPLS Tunnel
Check the Encryption parameters
→ Check the encryption parameters
Proceed as follows:
1. In FOXMAN-UN start the Ethernet Security Manager:
• NEM Desktop - Application - Ethernet Security Manager….
2. In the “Crypto Engines” tab check that all involved SENC1 Crypto Engines are synchronized and have the “Communication Status” set to “Ok”. The Crypto Engines connected to a core unit MPLS-TP port have the “Crypto Capable” parameter enabled.
3. In the “Crypto Termination Points” tab check that mapped core unit ports are listed and are synchronized.
4. In the “Crypto Configurations” tab check that the involved SENC1 Crypto Engines are listed with the correct incoming and outgoing LSP labels, and that they are mapped to the correct core unit MPLS-TP port.
Result: The encryption parameters are checked.
End of instruction