Post Upgrade Tasks
Make sure that all FOXMAN‑UN users in the database also exist as OS users. Refer to Creation of FOXMAN‑UN User Accounts.
Start up the FOXMAN‑UN system.
Start up the agents.
To avoid a workstation overload on start up, all agents are suspended after the upgrade. Start the agents one after the other at intervals to keep processor load reasonable.
Execute a forced polling.
Specially for nodes with MPLS-TP functionality a “Force Polling” command needs to be executed after the agent(s) startup.
ENP Resync
For nodes with MPLS-TP functionality the Expert Mode option in the Ethernet Networking Package (ENP) “Network - Synchronize” needs to be executed to make sure all node configurations are synchronized with the database.
Alarm synchronization.
Start a NEM Network Browser and use the menu “System - NE Synchronisation” for synchronization of all alarms with the database.
Verify system functions.
After the database upgrade has been completed successfully the database upgrade directory and its contents can be deleted.