Post Upgrade Tasks
• Make sure that all FOXMAN‑UN users in the database also exist as OS users. Refer to Creation of FOXMAN‑UN User Accounts.
• Start up the FOXMAN‑UN system.
• Start up the agents.
To avoid a workstation overload on start up, all agents are suspended after the upgrade. Start the agents one after the other at intervals to keep processor load reasonable.
• Execute a forced polling.
Specially for nodes with MPLS-TP functionality a “Force Polling” command needs to be executed after the agent(s) startup.
• ENP Resync
For nodes with MPLS-TP functionality the Expert Mode option in the Ethernet Networking Package (ENP) “Network - Synchronize” needs to be executed to make sure all node configurations are synchronized with the database.
• Alarm synchronization.
Start a NEM Network Browser and use the menu “System - NE Synchronisation” for synchronization of all alarms with the database.
• Verify system functions.
• After the database upgrade has been completed successfully the database upgrade directory and its contents can be deleted.