Hitachi Energy
mgNetworkAgentMgr.cfg
 
This file resides in /opt/nem/etc/genea
hb_num_missed_hb_for_log
Number of missed heartbeats until a log entry is made
default: 3
hb_num_missed_hb_for_alarm
Number of missed heartbeats until an alarm is raised
default: 6
EF: Event Filtering. Event Filtering mechanism which sends to the flooding list the NEs driving the EA event rate over the Continuous Event Rate (CER) and Burst Event Rate (BER) threshold. The system ignores all the alarm events of the NEs included in the flooding list. Alarms will be resynchronized automatically when the rate returns to normal values.
On Systems with more than 60 tunnels configured going through a node, set these 2 values to the maximum number of expected configured tunnels, plus an additional 10% (rounded up) to avoid delay on alarms.
To apply the defaults, keep the property commented with a preceding #. Uncomment desired property and change its value if required to apply different settings.
ef_enabled
Enable or disable Event Filtering mechanism on FOX61x agent.
default: true (set to false to disable)
ef_ne_cer_per_min
Continuous Event Rate (CER) threshold
default: 60
ef_ne_ber_per_min
Burst Event Rate (BER) threshold
default: 120
There are more parameters in this file - do not modify those entries in the file as that would pose a risk for system stability.