Hitachi Energy
nem.conf
 
Customer specific labeling:
company_name
Hitachi Energy Ltd
This parameter is not intended to be modified by the user.
product_name
FOXMAN‑UN
This parameter is not intended to be modified by the user.
build
18.x.y-abc
This parameter is not intended to be modified by the user.
buildtime
dd/mm/yyyy-hh:mm:ss
This parameter is not intended to be modified by the user.
General parameters:
new_services_domain_name <domain_name>
Add this parameter with <domain_name> set to the name of the domain to which you want new services to be added upon creation. When added to nem.conf, all services will be added to that domain upon creation.
If the option is set to a domain that does not exist, there will an ERROR trace in the log file.
lic_if
You may add this parameter with value “enp4s0” or a similar expression stating the LAN interface name of your core machine used for the license validation. Example:
lic_if   ens3
The interface name can be found via the command “ifconfig”.
cst_create_esw_control
Add this parameter with the option “on” to enable storing ESW to the NEM database upon automatic upload from a FOX61x node:
cst_create_esw_control   on
ifpoint_data_xmlrpc1_support
Add this parameter with the option “enable” to enable FOX660 support in NP:
ifpoint_data_xmlrpc1_support   enable
ifpoint_data_koap_support
Add this parameter with the option “enable” to enable FOX61x support in NP:
ifpoint_data_koap_support   enable
nbi_inventory_oss_address
Set the northbound inventory listening port IP address. The address can be set as follows:
To listen on localhost:
- localhost
- LOCALHOST
- 127.0.0.1
To listen on any / all addresses (not recommended for security reasons):
- ANY
- any
- "" (empty)
- 0
To listen to a specific IP address:
- <IPdot Address> (e.g.: 172.31.41.21)
 
Note:
The listening port “nbi_inventory_oss_port” is defined in nbcli.conf.
nbi_linetest_oss_address
Set the northbound linetest listening port IP address. The address can be set as follows:
To listen on localhost:
- localhost
- LOCALHOST
- 127.0.0.1
To listen on any / all addresses (not recommended for security reasons):
- ANY
- any
- "" (empty)
- 0
To listen to a specific IP address:
- <IPdot Address> (e.g.: 172.31.41.21)
 
Note:
The listening port “nbi_linetest_oss_port” is defined in nbcli.conf.
fo_ttps_num_vc12_transparent
The number of VC12 transparent TTPs in each VC4 related to STM-n interfaces on NEs of type FO. Set this parameter only if you need to terminate at least 1 VC12 on the FO’s STM-n interface.
Default value: 63
fo_ttps_num_vc12_terminated
The number of VC12 terminated TTPs in each VC4 related to STM-n interface on NEs of type FO. Set this parameter only if you need to terminate at least 1 VC12 on the FO’s STM-n interface.
Default value: 0
fo_ttps_num_vc12_clock
The number of VC12 clock TTPs in each VC4 related to STM-n interfaces on NEs of type FO. Set this parameter only if you need to terminate at least 1 VC12 on the FO’s STM-n interface.
Default value: 0