Importing ESW, CPS and Profile from FOX61x NE
Importing ESW currently stored in the FOX61x NE
• As an administrator, add the parameter “cst_create_esw_control on” in the file /opt/nem/etc/nem.conf.
• As an administrator, execute a “nemstop” and “nemstart” to activate the new setting. Users will need to log in to the
NEM Desktop again.
This will import the NE’s control unit ESW to the FOXMAN‑UN database if not currently stored in the database.
• From FOXCST shelf view, click on the service unit(s).
This will import the service unit’s ESW, if not available in the FOXMAN‑UN database.
• Verify that the ESW are imported in the NEM database:
From the
NEM Desktop, start the “ESW Tasks” dialog Window.
Then click on “File - Administration”. The “ESW Administration” window lists all the ESW stored in the NEM database.
Importing the CPS and Profiles currently stored in the FOX61x NE
• From the
NEM Desktop, start the “Profile & CPS Tasks” dialog (Network – Profile & CPS Tasks…).
• In the “Profile & CPS: Tasks” dialog, select “File – Administration…”
• In the “Profile & CPS: Administration” dialog, “Select NE”
• Select the appropriate CPS or Profiles to be imported from the “Profile & CPS on NE” dialog.
• Click the “<” or “<<” to import the selected files to the NEM database